Item no. 351
Waste water test set APS MULTI 4
Accessories DPG07, DPG02, LM06
The robust wastewater test set: hard-wearing test and leak test pads for leak testing sewer and wastewater pipes. The APS Multi 4 consists of hard-wearing sealing pads and test pipe pads made of a special rubber compound. These sealing pads are particularly suitable for sealing house connection pipes. Due to their short design and rounded ends, they can be easily inserted into the pipe.
The standard equipment includes eyelets on the sealing cushions and a retraction rope with carabiner.
The standard equipment includes eyelets on the sealing cushions and a retraction rope with carabiner.
Robust and durable
Durable test and sealing pads
Waste water and sewer
Leak test of sewer and wastewater pipes
Robust and secure hold: test bladder in the cleaning opening.
Technical details
Services
The APS Multi 4 optimally complements your RAU measuring devices for testing sewer and wastewater pipes.
You can find all the advantages here:
- Testing of wastewater pipes in accordance with DIN EN 1610 using the LC "air" method and a test pressure of 100 hPa
- Test tube cushion for diameters 80-150 mm with pneumatic connection for DPG02, DPG07 and LM06 TOUCH
- Test time depending on the pipe diameter and selectable on the test device
- Save measurement results, transfer data to a PC and print out logs incl. Diagram on DIN A4 - only with DPG07 TOUCH and LM06 TOUCH
- Hand pump with extension hose for inflating the sealing pads
- Expandable with pressure pump, for large line volumes (DPL, item no. 332 optional)
Scope of delivery
- Test pipe cushion with distributor NW 80-150 mm
- 3 sealing pads with NW 50-70 mm, NW 70-100 mm and NW 100-150 mm
- Hand pump with pump hose - couplings and nozzle (NW 2.7)
- APS adapter for compressor (NW 7.2)
- Extension hose 2.0 m
- Pull rope with carabiner
- Sortimo L-BOXX case
EAN GTIN
APS MULTI 4: 4262453340553
WPS FUNK
Useful accessories
| Pressure pump up to 3 bar | Air pressure pump for oil-free inflation up to 3 bar |
Item no. 70130
External RADIO pressure sensor from 0.3 bar to 20 bar test pressure and test medium water or air. Suitable for DPG07 TOUCH.
Test and measure over longer distances without cables! (can also be used with LM06 and DPG02 via the USB charging cable supplied)
Application
Leak and load testing on pipes up to 20 bar: Leak and stress test of drinking water installations, heating and solar systems with compressed air, inert gas or water. Long-term measurements with freely selectable interval time. Even inadequate locations and long distances are possible wirelessly thanks to the radio connection.
- Leak and stress test of water pipes with water or air as a medium in accordance with DIN EN 806-4 from 0.15 bar (0.015 MPa) up to a maximum of 20 bar (2 MPa)
- Wireless pressure sensor ideal for DPG07 TOUCH – check and measure over longer distances without cables
- Can also be used with LM06 TOUCH and DPG02 TOUCH via magnetic charging cable
- WPS FUNK fits into the foam insert of the DPG07 TOUCH test instrument case
- Wireless pressure sensor
- USB charging cable and USB charger
Item no. 70115
External cable pressure sensor for test pressures from 0.3 to 20.0 bar, test medium water or air, suitable for RAU LM06 and DPG02 TOUCH or DPG07 TOUCH measuring devices.
Application
Leak and load testing on pipes up to 20 bar: Leak and stress test of drinking water installations, heating and solar systems with compressed air, inert gas or water. Long-term measurements with freely selectable interval time.
- Leak and stress test of water pipes with water or air as a medium in accordance with DIN EN 806-4 from 0.15 bar (0.015 MPa) up to a maximum of 20 bar (0.2 MPa)
- External pressure sensor suitable for LM06, DPG02 and DPG07 TOUCH
- Measuring armature with 3 meter USB cable for secure data transmission
- Cable pressure sensor
Item no. 76089
Shut-off bladder DN 300, robust and hard-wearing design
Can be loaded up to max. 0.4 bar
RAU Shut-off bladder DN 300 mm, for APS SOFT
Art. No. 76089
Item no. 76088
Shut-off bladder DN 250, robust and hard-wearing design
Can be loaded up to max. 0.4 bar
RAU Shut-off bladder DN 250 mm, for APS SOFT
Art. No. 76088
Item no. 76087
Shut-off bladder DN 200, robust and hard-wearing design
RAU Shut-off bladder DN 200 mm, for APS SOFT
Can be loaded up to max. 0.4 bar
Art. No. 76087
Item no. 76086
Shut-off bladder DN 150, robust and hard-wearing design
Can be loaded up to max. 0.4 bar
RAU Shut-off bladder DN 150 mm, for APS SOFT
Art. No. 76086
Item no. 448
Thread test piece for water with pneumatic connection NW 7.2, GPW 2 1/2″
Thread test adapter
Art. No. 448
Item no. 447
Thread test piece for water with pneumatic connection NW 7.2, GPW 2″
Thread test adapter
Art. No. 447
Item no. 73744
Two in one: ballpoint pen (blue) and touch function for operating the measuring device display, all the details:
- Twist action ballpoint pen made of lacquered metal
- Touch function for operating the measuring device display, cell phones, tablets, etc.
- incl. RAU laser engraving
- Ink color: blue, indelible
- Color: blue
- Refill replaceable
- DPG TOUCH Pen Pen / Ballpoint pen SlimLine Touchpen
Item no. 99001
Limited edition bottle opener with key ring, size: 75 x 10 x 3 mm
- High-quality aluminum
- RAU logo laser engraved on the top
- incl. key ring