Item no. 341
Waste water test kit APS Soft
Accessories DPG07, DPG02, LM06
The flexible waste water test set: Leak test of waste water pipes in building installations.
Durable
You can rely on high quality
Check waste water
Leak test of wastewater pipes
Testing a condensing boiler stack and inflating the test bladder with bellows; test bladder in the cleaning opening of a waste water pipe.
Technical details
Services
The APS Soft optimally complements your RAU measuring devices for testing waste water pipes and condensing boilers.
You can find all the advantages here:
- Testing of wastewater pipes in accordance with DIN EN 1610 using the LC "air" method and a test pressure of 100 hPa
- Mainly used for testing newly installed wastewater pipes in domestic installations
- Test bladder for diameters 50-150 mm with pneumatic connection for the DPG07, DPG02 and LM06 TOUCH
- 3 shut-off bladders for pipe diameters 50, 100 and 50-150 mm
- Bellows for inflating the test and shut-off bladders
- Test time depending on the pipe diameter and selectable on the test device
- Save measurement results, transfer data to a PC and print out logs incl. Diagram on DIN A4 - only with DPG07 TOUCH and LM06 TOUCH
- Other possible applications: Leak testing of condensing stoves (chimney testing)
Scope of delivery
- Test bladder 50-150 mm
- 3 shut-off bladders 50 mm, 100 mm, 50-150 mm
- Bellows with pressure gauge
- Plastic case
EAN GTIN
APS SOFT: 4262453340348
WPS FUNK
Useful accessories
| Pressure pump up to 3 bar DPL | Air pressure pump for oil-free inflation up to 3 bar |
Item no. 4175
The coupling is used to test water lines with compressed air.
The special test adapter is compatible with our FGP fine-thread test adapter set for drinking water testing.
! CAUTION !
Never connect a filled water line directly to the measuring device (yellow test hose)!
Item No. 4175
Item no. 66990
Set with stop and washers for TSCH XP Eaves Closer
The set consists of the stop (slotted hole), two washers, and the orange clamping lever, see image.
Item No. 66990
Item no. 66989
Long PVC jaws for Eaves Closer TSCH XP
, including rivets
Is the long PVC jaw on your Eaves Closer worn out? Simply replace it!
For seaming without scratching delicate surfaces and color-coated metal sheets.
Item No. 66989
EAN GTIN 4262453341383
Item no. 66988
Short PVC jaw with rubber insert for Eaves Closer TSCH XP
, including rivets
Is the short PVC jaw on your Eaves Closer worn out? Simply replace it!
For seaming without scratching delicate surfaces and color-coated metal sheets.
Item No. 66988
EAN GTIN 4262453341376
Item no. 66987
Replacement PVC jaws for the Eaves Closer TSCH XP
including rivets
Are the PVC jaws on your Eaves Closer worn out? Simply replace them with this set!
For seaming without scratches on sensitive surfaces and color-coated metal sheets.
Item No. 66987
EAN GTIN 4262453341369
Item no. 70130
External RADIO pressure sensor from 0.3 bar to 20 bar test pressure and test medium water or air. Suitable for DPG07 TOUCH.
Test and measure over longer distances without cables! (can also be used with LM06 and DPG02 via the USB charging cable supplied)
Application
Leak and load testing on pipes up to 20 bar: Leak and stress test of drinking water installations, heating and solar systems with compressed air, inert gas or water. Long-term measurements with freely selectable interval time. Even inadequate locations and long distances are possible wirelessly thanks to the radio connection.
- Leak and stress test of water pipes with water or air as a medium in accordance with DIN EN 806-4 from 0.15 bar (0.015 MPa) up to a maximum of 20 bar (2 MPa)
- Wireless pressure sensor ideal for DPG07 TOUCH – check and measure over longer distances without cables
- Can also be used with LM06 TOUCH and DPG02 TOUCH via magnetic charging cable
- WPS FUNK fits into the foam insert of the DPG07 TOUCH test instrument case
- Wireless pressure sensor
- USB charging cable and USB charger
Item no. 70115
External cable pressure sensor for test pressures from 0.3 to 20.0 bar, test medium water or air, suitable for RAU LM06 and DPG02 TOUCH or DPG07 TOUCH measuring devices.
Application
Leak and load testing on pipes up to 20 bar: Leak and stress test of drinking water installations, heating and solar systems with compressed air, inert gas or water. Long-term measurements with freely selectable interval time.
- Leak and stress test of water pipes with water or air as a medium in accordance with DIN EN 806-4 from 0.15 bar (0.015 MPa) up to a maximum of 20 bar (0.2 MPa)
- External pressure sensor suitable for LM06, DPG02 and DPG07 TOUCH
- Measuring armature with 3 meter USB cable for secure data transmission
- Cable pressure sensor
Item no. 76089
Shut-off bladder DN 300, robust and hard-wearing design
Can be loaded up to max. 0.4 bar
RAU Shut-off bladder DN 300 mm, for APS SOFT
Art. No. 76089
Item no. 76088
Shut-off bladder DN 250, robust and hard-wearing design
Can be loaded up to max. 0.4 bar
RAU Shut-off bladder DN 250 mm, for APS SOFT
Art. No. 76088