{"id":25358,"date":"2024-04-02T16:28:01","date_gmt":"2024-04-02T14:28:01","guid":{"rendered":"https:\/\/www.rau-systems.de\/gas-load-test-with-the-dpg07-touch\/"},"modified":"2024-10-22T08:00:36","modified_gmt":"2024-10-22T06:00:36","slug":"gas-load-test-with-the-dpg07-touch","status":"publish","type":"post","link":"https:\/\/www.rau-systems.de\/en\/anwendung-ratgeber\/gas-load-test-with-the-dpg07-touch\/","title":{"rendered":"Gas load test with the DPG07 TOUCH"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"25358\" class=\"elementor elementor-25358 elementor-19057\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-cd5f9dc elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"cd5f9dc\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-custom\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-29f3df6\" data-id=\"29f3df6\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-421a6c6 elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"421a6c6\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<span class=\"elementor-heading-title elementor-size-default\">the measurement as a video<\/span>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6921212 rau-product-title elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"6921212\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Video on load testing with the DPG07<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2268428 elementor-widget elementor-widget-text-editor\" data-id=\"2268428\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>In this video, Mr. Rau shows you the individual steps of the load test with the RAU DPG07 TOUCH pressure tester.<\/p>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-28a953c elementor-invisible elementor-widget elementor-widget-video\" data-id=\"28a953c\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;youtube_url&quot;:&quot;https:\\\/\\\/youtu.be\\\/T77u5uvrfBs&quot;,&quot;_animation&quot;:&quot;fadeInUp&quot;,&quot;video_type&quot;:&quot;youtube&quot;,&quot;controls&quot;:&quot;yes&quot;}\" data-widget_type=\"video.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-wrapper elementor-open-inline\">\n\t\t\t<div class=\"elementor-video\"><\/div>\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-443ef3a\" data-id=\"443ef3a\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-bb8b2e0 elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"bb8b2e0\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<span class=\"elementor-heading-title elementor-size-default\">Step by step<\/span>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-27cd826 rau-product-title elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"27cd826\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">How the measurement is carried out<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6e5e395 elementor-widget elementor-widget-text-editor\" data-id=\"6e5e395\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ol>\n<li>Enter object \/ customer and inspector<\/li>\n<li>Menu: Tap<strong>&#8220;Check gas pipe<\/strong>&#8221; and<strong>&#8220;Load test<\/strong>&#8220;<\/li>\n<li>Mounting threaded test pieces<\/li>\n<li>Connect Y-hose and test hose to DPG07<\/li>\n<li><strong>Start pump<\/strong> as soon as test pressure is reached Start program with green start LED<\/li>\n<li><strong>Automatic measuring sequence starts<\/strong> (5 minutes adjustment time for pressure equalization and 10 minutes test time)<\/li>\n<li>Measuring device beeps and test report is automatically printed out, measurement result saved on the SD card<\/li>\n<\/ol>\n<p><strong>Note: The leak test is carried out after the load test.<\/strong> <\/p>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>The <strong>load test<\/strong> is a prescribed measurement in accordance with TRGI for <strong>newly laid natural gas pipes<\/strong> (at 1 bar). The measurement is explained here step by step using the <strong>DPG07 TOUCH<\/strong>. <\/p>\n","protected":false},"author":336,"featured_media":25361,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[262,330,231,326,324],"tags":[243,329,332,331],"class_list":["post-25358","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-dpg07-touch-en","category-load-test","category-measuring-devices","category-natural-gas","category-testing-measurement-application","tag-dpg07-en","tag-gas-en","tag-load","tag-load-test"],"_links":{"self":[{"href":"https:\/\/www.rau-systems.de\/en\/wp-json\/wp\/v2\/posts\/25358","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.rau-systems.de\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.rau-systems.de\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.rau-systems.de\/en\/wp-json\/wp\/v2\/users\/336"}],"replies":[{"embeddable":true,"href":"https:\/\/www.rau-systems.de\/en\/wp-json\/wp\/v2\/comments?post=25358"}],"version-history":[{"count":0,"href":"https:\/\/www.rau-systems.de\/en\/wp-json\/wp\/v2\/posts\/25358\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.rau-systems.de\/en\/wp-json\/wp\/v2\/media\/25361"}],"wp:attachment":[{"href":"https:\/\/www.rau-systems.de\/en\/wp-json\/wp\/v2\/media?parent=25358"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.rau-systems.de\/en\/wp-json\/wp\/v2\/categories?post=25358"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.rau-systems.de\/en\/wp-json\/wp\/v2\/tags?post=25358"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}